HBO 10 MO/16-1G
Insulation material |
Molybdenum |
Volume (l) |
10 |
Tmax vacuum (°C) |
1600 |
więcej infomacji
mniej informacji
Wymiary: Zewnętrzne Wys. x Szer. x Głęb. |
2500 x 2300 x 2000 |
Transport weight (kg) |
1800 |
Usable space |
|
Ø x H, usable space without retort (mm) |
200 x 300 |
Ø x H, usable space with retort (mm) |
180 x 280 |
Thermal values |
|
Tmax atmospheric pressure (°C) |
1600 |
-Delta-T, above 800°C (K) according to DIN 17052 |
± 10 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
3 |
Connecting values |
|
Moc (kW) |
50 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 125 |
Series fuse (A) |
3 x 160 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
Cooling water required |
|
Flow (l/min) |
40 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
500-2000 |
Controller |
Siemens |
HBO 25 MO/16-1G
Insulation material |
Molybdenum |
Volume (l) |
25 |
Tmax vacuum (°C) |
1600 |
więcej infomacji
mniej informacji
Wymiary: Zewnętrzne Wys. x Szer. x Głęb. |
2500 x 2300 x 2000 |
Transport weight (kg) |
2000 |
Usable space |
|
Ø x H, usable space without retort (mm) |
300 x 400 |
Ø x H, usable space with retort (mm) |
280 x 380 |
Thermal values |
|
Tmax atmospheric pressure (°C) |
1600 |
-Delta-T, above 800°C (K) according to DIN 17052 |
± 10 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
4 |
Connecting values |
|
Moc (kW) |
65 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 100 |
Series fuse (A) |
3 x 125 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
Cooling water required |
|
Flow (l/min) |
50 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
500-2000 |
Controller |
Siemens |
HBO 60 MO/16-1G
Insulation material |
Molybdenum |
Volume (l) |
60 |
Tmax vacuum (°C) |
1600 |
więcej infomacji
mniej informacji
Wymiary: Zewnętrzne Wys. x Szer. x Głęb. |
2800 x 2300 x 2500 |
Transport weight (kg) |
3000 |
Usable space |
|
Ø x H, usable space without retort (mm) |
400 x 500 |
Ø x H, usable space with retort (mm) |
380 x 480 |
Thermal values |
|
Tmax atmospheric pressure (°C) |
1600 |
-Delta-T, above 800°C (K) according to DIN 17052 |
± 10 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
5 |
Connecting values |
|
Moc (kW) |
80 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 120 |
Series fuse (A) |
3 x 160 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
Cooling water required |
|
Flow (l/min) |
64 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
500-2000 |
Controller |
Siemens |
HBO 10 W/22-1G
Insulation material |
Tungsten |
Volume (l) |
10 |
Tmax vacuum (°C) |
2200 |
więcej infomacji
mniej informacji
Wymiary: Zewnętrzne Wys. x Szer. x Głęb. |
2500 x 2300 x 2000 |
Transport weight (kg) |
1800 |
Usable space |
|
Ø x H, usable space without retort (mm) |
200 x 300 |
Ø x H, usable space with retort (mm) |
180 x 280 |
Thermal values |
|
Tmax atmospheric pressure (°C) |
2200 |
-Delta-T, above 800°C (K) according to DIN 17052 |
± 10 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
4 |
Connecting values |
|
Moc (kW) |
125 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 180 |
Series fuse (A) |
3 x 250 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
Cooling water required |
|
Flow (l/min) |
100 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
500-2000 |
Controller |
Siemens |
HBO 25 W/22-1G
Insulation material |
Tungsten |
Volume (l) |
25 |
Tmax vacuum (°C) |
2200 |
więcej infomacji
mniej informacji
Wymiary: Zewnętrzne Wys. x Szer. x Głęb. |
2500 x 2300 x 2000 |
Transport weight (kg) |
2000 |
Usable space |
|
Ø x H, usable space without retort (mm) |
300 x 400 |
Ø x H, usable space with retort (mm) |
280 x 380 |
Thermal values |
|
Tmax atmospheric pressure (°C) |
2200 |
-Delta-T, above 800°C (K) according to DIN 17052 |
± 10 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
5 |
Connecting values |
|
Moc (kW) |
150 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 220 |
Series fuse (A) |
3 x 315 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
Cooling water required |
|
Flow (l/min) |
120 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
500-2000 |
Controller |
Siemens |
HBO 60 W/22-1G
Insulation material |
Tungsten |
Volume (l) |
60 |
Tmax vacuum (°C) |
2200 |
więcej infomacji
mniej informacji
Wymiary: Zewnętrzne Wys. x Szer. x Głęb. |
2800 x 2300 x 2500 |
Transport weight (kg) |
3000 |
Usable space |
|
Ø x H, usable space without retort (mm) |
400 x 500 |
Ø x H, usable space with retort (mm) |
380 x 480 |
Thermal values |
|
Tmax atmospheric pressure (°C) |
2200 |
-Delta-T, above 800°C (K) according to DIN 17052 |
± 10 |
Max. heat-up rate (K/min) |
10 |
Cooling time (h) |
6 |
Connecting values |
|
Moc (kW) |
250 |
Voltage (V) |
400 (3P) |
Current (A) |
3 x 380 |
Series fuse (A) |
3 x 500 |
Vacuum (option) |
|
Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
Cooling water required |
|
Flow (l/min) |
200 |
Gas supply |
|
Nitrogen or Argon flow, others on request (l/h) |
500-2000 |
Controller |
Siemens |
Z zastrzeżeniem zmian technicznych i błędów